Diesel and natural gas generatorsAd id: 97 | Views : 3891
Price : Please contact
Date listed : 2010-04-06

Chicago, Illinois

please call Steven at 630-258-2543


40958013
Used- Wacker G50 Mobile Diesel Generator Set, 42 kW standby, 38 kW prime. John Deere model 4045DF270D engine, serial #PE40450415845. Marathon Magnaplus generator end 3/60/208/240/460/480V also rated 1/60/120/240 (as single phase 35 kW standby, 32 kW prime). Sound enclosure rated 66 dBA at 23’. Fuel tank 89 gallon capacity. Single axle trailer Wacker details

More Info KW: 60
Manufacturer: Caterpillar
Fuel: NATURAL GAS
Volts: 120/240
41689001
Used-CAT / Olympian 60 kW Natural Gas Generator Set, model G60F1, serial #E0519A/001. Ford Motor Co natural gas engine, model WSG1068, V10. 3/60/120/240V. Hours 255, year 1999. details

More Info KW: 65
Manufacturer: KATOLIGHT
Fuel: NATURAL GAS
Volts: 120/208
41737001
Used- Katolight 65 kW Natural Gas Generator Set. Katolight unit model N65FPH4, unit SN-AD163473SRH E-40367. Hercules model GT3400 natural gas engine SN-JU3336239 G3400TX356. 3/60/120/208 volts, 1800 rpm. Mainline circuit breaker. Sound attenuated enclosure. 25 hours. Unit was tested in our yard, no-load, by Patten Cat 8-27-09. details

More Info KW: 70
Manufacturer: CUMMINS
Fuel: NATURAL GAS
Volts: 120/208/277/480
42003001
Unused- Cummins 70 KW Standby Rated Natural Gas Generator Set. Cummins model GGHF, SN-L060999120. Ford model WSG1068, SN-06QS60833 natural gas engine. Newage /Stamford 3/60/120/208/277/480 volt, 1800 rpm. Rated 70 kW three phase and 46.9 kW as single phase. Power command digital control panel. Main-line circuit breaker rated 160/400 amp. Block heater. 12 V details

More Info KW: 110
Manufacturer: MQ POWER
Fuel: DIESEL
Volts: 120/208/277/480
41973001
Used- MQ Power / Multiquip Whisperwatt trailered 110 kW standby rated / 100 kW prime rated diesel generator set. Whisperwatt model DCA-125SSJU, SN-7500387. John Deere model 6068TF250, SN-PE6068T055366, 6 cylinder, 4 cycle turbocharged engine rated 150 hp @ 1800 rpm. Generator model DB-1381J, 3/60/240/480 volt, reconnectable to 208, 220, 240, 416, 440, details

More Info KW: 150
Manufacturer: Katolight
Fuel: diesel
Volts: 488
42345001
Used-Katolight Generator Set. Diesel powered. Engine is Cummings 855 Big Cam. 150 kW. 300 amp circuit breaker. 9 wire reconnectable for single or three phase. Currently configured for 488 volt, 3 phase. Fresh oil and filter change. (2) Brand new industrial batteries. On board fuel booster tank, approximately 20 gallons. Missing the end door to the enclosure. details

More Info KW: 160
Manufacturer: Mercedes
Fuel: diesel
Volts: 400
42173001
Used-Mercedes 160 kW Diesel Generator. 200 kVA/ 50 hz/1500 rpm, 236 running hours. AvK generator, 173 kW/217 kVA/400V/3 phase, 50 hz, 313 amps. With control panel, all related parts. Used as standby generator. details

More Info KW: 200
Manufacturer: Kohler
Fuel: Diesel
Volts: 277/480
42297001
Used-Kohler 200 kW diesel standby generator set.Kohler model 200R0ZD71, SN-355911.Detroit Diesel model 6-71T turbocharged engine. 3/60/277-480V.12 lead re-connectable.main-line circuit breaker. Battery charger. Block heater. Sub-base fuel tank. 245 hours. details

More Info KW: 200
Manufacturer: BALDOR
Fuel: DIESEL
Volts: 120/208/240//480
41995001
Used- Baldor Model TS250T Mobile 200kW Standby Rated/182kW Continuous Rated Diesel Generator Set. John Deere diesel engine model 6068HF475 rated 314 hp @ 1800 rpm, 6 cylinder turbocharged air cooled, EPA tier 2. Voltage 3 phase adjustable. 120/208/220/240/416/440/460/480V, single phase adjustable 120/127/139/240/254/277. 3 postion reconnection switch for voltage details

More Info KW: 225
Manufacturer: Caterpillar
Fuel: diesel
Volts: 277/480
41160003
Used-Cat XQ225 Diesel Generator Set. Cat model 3306 engine. Cat model SR4 alternator, 3/60/277/480V, 225 kW, 281.25 kva, 338 amps, 1800 rpm, 0.8 pf, 12 lead, standby rating. Sound attenuated enclosure. 6300 hours. Year 1997. details

More Info KW: 250
Manufacturer: KOHLER
Fuel: DIESEL
Volts: 120/208/240/277/480
41804001
Used- Kohler 250 kW Diesel Genset. Kohler model 250ROZD71, serial #265291. Detroit 6V-92TA, turbocharged aftercooled engine rated 415 hp at 1800 rpm. 120/208V, 12 lead reconnectable to 480V and 120/240 single phase, 600 amp mainline circuit breaker. Includes block heater, 10 amp battery charger, weather enclosure. 122 hours. details

More Info KW: 250
Manufacturer: Caterpillar
Fuel: DIESEL
Volts: 208/277/480
41919001
Used- CAT 250 kW standby rated diesel generator set. CAT 3406 engine SN-2WB01367 Arr#4W3812, rated 375 hp @ 1800 rpm. Cat model SR4 generator end SN-5GA03453 Arr #5N5062 3/60/208-277-480V. Mainline circuit breaker. Tramont 650 gallon sub-base fuel tank. Drop over enclosure with muffler. 675 hours. details

More Info KW: 300
Manufacturer: CUMMINS
Fuel: DIESEL
Volts: 208-240/416-480
522378
NEW- Cummins Powered 300 kW Standby Diesel Generator Set. Cummins QSM11-G4 EPA tier 3 engine rated 470 hp @ 1800 rpm. Marathon generator model 432CSL6212, 3/60/208-240/416-480V, 1800 rpm. Currently set up for 480V, 12 wire reconnectable, 0.8 power factor, NEMA H (150C). Includes 500 gallon sub-base double wall fuel tank with gauge kit, radiator, digital details

More Info KW: 350
Manufacturer: CUMMINS ONAN
Fuel: DIESEL
Volts: 277/480
42117001
Used- Cummins Onan 350 kW Diesel Generator Set, Model 350DFCC, Unit SN-L950594172. Cummins NTA855-G3 engine SN-11791412, rated 535 HP @ 1800 RPM, turbocharged and aftercooled. 3/60/277/480V. Main-line circuit breaker. Power Command control panel. Weather enclosure, sub-base fuel tank, block heater.370 hrs. Yr. 1995. details

More Info KW: 352
Manufacturer: MQ POWER / MULTIQUIP
Fuel: DIESEL
Volts: 120/208/277/480
41783001
Used- MQ Power / Multiquip Whisperwatt 352 kW Standby /320 kW Prime Rated Diesel Generator Set. Whisperwatt model DCA-400SSK, SN-3703872. Komatsu model SA6D14OE-2, SN-28527, 6 cylinder 4 cycle, 478 hp @ 1800 rpm, turbocharged aftercooled engine. Generator 3/60/240/480 volt, reconnectable to 208, 220, 240, 416, 440, 480 volts, available single phase 120,127,139,240,254,277. details

More Info KW: 365
Manufacturer: CUMMINS
Fuel: DIESEL
Volts: 277-480
40828001
Used- Cummins 365 kW Diesel Generator Set. Cummins KTA1150GS1 engine, serial #31124623. 565 hp at 1800 rpm. Model 502FDR7022GHW, serial #LM-93903-11/20-4, 3/60/277/480V, 1800 rpm, mainline circuit breaker, currently set up for 480V. Includes a weather enclosure. 570 hours. Note: Turbo was removed and sealed, rust inhibitor sprayed per Cummins long term details

More Info KW: 400
Manufacturer: CUMMINS
Fuel: DIESEL
Volts: 120/208/277/480
42090006
Used- Cummins Diesel Generator, 400 kW, 500 kva, model 680F0C41DA; engine model VT12700GS, serial #2172638. 3/60/120/208/277/480V. 1868.3 hours. details

More Info KW: 448
Manufacturer: Caterpillar
Fuel: natural gas
Volts: 480
40958012
Used-Caterpillar G3512NA Natural Gas Generator Set. Includes air cleaner assemblies and elements, install 800 amp circuit breaker with enclosure, install Murphy engine controls, instrument panel. 3/60/480V induction end rated 448 kW. (Note: engine will pull 400kW.) Unit to be assembled and load bank tested. details

More Info KW: 450
Manufacturer: Cummins
Fuel: natural gas
Volts: 208
40958008
Used-Cummins 450 kW Natural Gas Generator Set. Cummins GTA28 natural gas engine. Currently set up at 120/208V, 12 lead reconnectable end. Drop over enclosure. 295 hours. Year 1997. details

More Info KW: 500
Manufacturer: Cummins
Fuel: natural gas
Volts: 120/208/277/480
41872001
New Cummins 500 kW Natural Gas Generator Set. Cummins model GTA28 natural gas engine, 10:1 compression ratio, rated 770 hp @ 1800 rpm. Newage generator, PMG excitation (factory package) currently wired 120/208, 12 lead re-configurable to 480 main line circuit breaker, 2000 amp with adjustable trip setting. Cummins PCC2100 Power Command microprocessor control details

More Info KW: 500
Manufacturer: Cummins
Fuel: diesel
Volts: 208-240/416-480
13645044
New 500 kW Cummins powered standby diesel generator set. Cummins QSX15-G9, SN-79344657 EPA tier 2 engine rated 755 hp @ 1800 rpm. Marathon generator model 572RSL4027 with DVR2000E regulator UL labeled w/PMG. 3/60/208-240/416-480V. Currently set up for 480V. 12 wire reconnectable, 0.8 power factor, NEMA H (130 C) radiator, digital model DGC2020 control details

More Info KW: 500
Manufacturer: Kohler
Fuel: Diesel
Volts: 277/480
41160014
Used- Kohler 500 kW Diesel Generator Set, model 500ROZ71. Cummins model VTA28G1 diesel engine rated 760 hp @ 1800 rpm, Marathon 3/60/277/480V, 1161 hours, weather proof enclosure. details

More Info KW: 528
Manufacturer: Multiquip
Fuel: diesel
Volts: 480
40958010
Used-Multiquip Model DCA-600SSK Diesel Generator. Engine model Komatsu SA6D170AE1 standby rated 528 kW/660 kVA. Prime power rated 480 kW/600 kVA. 40' double axle trailer, 500 gallon DW fuel tank. Approximately 5540 hours. details

More Info KW: 600
Manufacturer: Detroit
Fuel: Diesel
Volts: 277/480
40958014
Used- Detroit Diesel 600kW, model 12VF12499 engine, 3/60/277-480V, sound enclosure, 1150 gallon sub-base fuel tank, 260 hrs, 1997. details

More Info KW: 750
Manufacturer: Detroit
Fuel: Diesel
Volts: 277/480
40859002
Used- Detroit Diesel 750 kW diesel generator set. Detroit Diesel 16V92T engine, 1095 brake horsepower, serial #16VF006867. Marathon Electric Magna One 3/60/277/480V, 1800 rpm, model 680FDR8068GG-P282W, serial #SL 3328477-02, 1200 amp mainline circuit breaker. Simplex modular control. Weather enclosure. 314 hours. Yr. 1986. details

More Info KW: 750
Manufacturer: Cummins
Fuel: Diesel
Volts: 480
41160011
Used Cummins / Onan 750 kW Diesel Generator Set. Cummins QST30G1 engine. Onan model DFHA 3/60/277/480V, 1800 rpm, 0.8 pf, 10 lead, standby rating, 1250 amp breaker. Drop-over weatherproof enclosure. UL listed day tank. 213 hours. Year 1999. details

More Info KW: 775
Manufacturer: CUMMINS
Fuel: DIESEL
Volts: 277/480
89395
Used- Cummins 775 kW Diesel Generator Set. Cummins model KTA38-GI engine, serial #31132466, rated 1135 hp at 1800 rpm. O'Brien generator end, 3/60/277/480 volt, model OB775KWDW63, serial #3029. Currently set up for 480 volt, 1165 amps, 1200 amp mainline circuit breaker. Sub-base fuel tank. Weather enclosure. 713 hours. Load bank tested. details

More Info KW: 842
Manufacturer: Perkins
Fuel: gas
Volts: 400
42173002
Used-Perkins Gas Generator, 842 kW, type 4015 TESI 140 H/C, 230-400V/50 hz/1500 rpm, run 36,000 hours with revision at 26,000 hours. Complete with control panel and accessories. details

More Info KW: 1100
Manufacturer: Cummins
Fuel: natural gas
Volts: 480
41725002
Used-Cummins 1100 kW Cont Rated Natural Gas Generator Set. Cummins QSV81-G engine, 1200 rpm. Newage Stamford end, 3/60/480V. Americool remote radiator. 5527 hours. Built 2002. details

More Info KW: 1250
Manufacturer: Cummins
Fuel: diesel
Volts: 415
42269001
Used-Cummins Diesel Engine KTA 50 G3. 1.25 mw diesel generator, serial #33127342. Leroy Somer alternator, serial #162186-1. 415 volts, 1500 rpm, 50 hz. Year 1994. 3830 hours run. Partitioined diesel room housing a gallon (1000 liter) fuel tank. 40' acoustic container, 2500A 3 pole ACB, control panel, batteries and exhaust silencer. details

More Info KW: 1250
Manufacturer: Caterpillar
Fuel: diesel
Volts: 480
41160005
Used-Cat XQ1250 kW 3/60/277-480V. Cat model 3512 DITA engine, SR-4B generator end. Mounted in a portable 40' 2 axle trailer, 72 DBA sound attenuation. 1250 gallon double wall dual tank. 554 hours. Year 1999. details

More Info KW: 1250
Manufacturer: CUMMINS / Onan
Fuel: DIESEL
Volts: 480
42187001
Used- Cummins 1250 kW standby / 1100 kW prime diesel generator set. Cummins 1250 DFLC, SN-K950592302. Cummins model KTA50-G3 engine turbocharged aftercooled SN-K950592302. 3/60/480V. 2000 Amp main-line circuit breaker. PowerCommand control panel. 250 gallon day tank. Dual block heaters. Battery charger. Mufflers. Aluminum weather enclosure. 1648 hrs. details

More Info KW: 1500
Manufacturer: Cummins / Onan
Fuel: DIESEL
Volts: 480
42246001
Used- Cummins / Onan 1500 kW standby diesel generator set, model1500DFMB, SN-G920477218. Cummins model KTTA50-G2 engine. 3/60/277/480V. Hrs 150. Yr 1992. details

More Info KW: 1500
Manufacturer: Wartsila
Fuel: diesel
Volts: 380
42249001
Used-SACM-Wartsila Group Diesel Generator, type G12VS / PA100560. Effect: 1500 kva. Motor: SACM Mulhouse, type A.G.O. G12VS, serial #3365. Generator: UNELEC-Alsthom, serial #PA100560. Voltage: 380 volt/50 cycle/3 ph - 1000 rpm. Fuel: diesel LO1. Includes all periphery equipment: coolers, control panel for emergency start, exhaust units and silencers. Frame details

More Info KW: 1500
Manufacturer: Caterpillar
Fuel: diesel
Volts: 12470
41160004
Used-Cat 1500 kW Continuous Rated Diesel Generator Set. Cat model 3516 DITA engine, Katomodel A241980000 generator end, 3/60/7200-12470V. 653 hours. Year 1987. details

More Info KW: 2000
Manufacturer: Cummins
Fuel: diesel
Volts: 480
41574001
New Cummins 2000 kW Diesel Generator Set. Cummins model 2000DQKC, Cummins QSK60-G6 engine. 3/60/277/480V. Paralleling isolated bus. 2009 production. details

More Info KW: 2000
Manufacturer: Cummins
Fuel: diesel
Volts: 208-240/416-480
40977001
New Cummins 2000kW Standby Rated Diesel Generator Set, model DQKAB. Cummins model QSK60-G6 diesel engine rated 2922 hp @ 1800 rpm turbocharged, aftercooled . Newage model DQKAB-7221741, 3/60/277/480V generator end. Cummins Power Command digital control panel. 1 year/1500 hour warranty. Year 2008. details

More Info KW: 2060
Manufacturer: Caterpillar
Fuel: diesel
Volts: 480
41632002
Used-Cat 2060 kW Diesel Generator Set. Cat 3516B engine, model SR4B-GD generator end. 3/60/480V, 3097 amps, 7292 hours, year 2007. details

More Info KW: 5100
Manufacturer: Alstom
Fuel: gas
Volts: 4160
523533
USED: Alstom Tornado 5.1 mw gas turbine generator set, 3/60/4160V. Kato generator. 11,299 btu/kwh (lhv). 11,085 rpm speed. The package includes the following auxiliary equipment: natural gas treatment system, 480 volt motor control center, main switch gear, generator control panel, turbine programmable control system, turbine control panel and vibrating details

More Info KW: 5200
Manufacturer: Solar
Fuel: natural gas
Volts: 13800
11729003
Used-5200 kW Solar Taurus 60 mobile mounted gas turbine generating unit. 3/60/13.8 kv. Primary fuel natural gas. Equipped with starting systems, controls, switchgear systems, air filter and exhaust systems. 1510 hrs, 186 starts. Manufactured in 2001. details

More Info KW: 5200
Manufacturer: Solar
Fuel: natural gas
Volts: 13800
11729004
Used-5200 kW Solar Taurus 60 mobile mounted gas turbine generating unit. 3/60/13.8 kv. Primary fuel natural gas. Equipped with starting systems, controls, switchgear systems, air filter and exhaust systems. 1522 hrs, 226 starts. Manufactured in 2001. details

More Info KW: 23000
Manufacturer: ABB
Fuel: natural gas or diesel oil
Volts:
41746005
Used-23 MW ABB GT-10 Gas Turbine Power Generator Package, runs on natural gas or diesel oil MK 10, efficiency 29.2%. Electrical start system, heat rate 9986 btu/kW, emissions on 100% load: NoX 34.76 ppm. CO 8.1 ppm, 49528 hours run. Gearbox by BHS Voith, model TG 90 S, 7722/15000 rpm. (1) Water cooled alternator by ABB, power output 39,600 kkva at 1500 rpm details